Q:
- td (l->h) => 7.277 nSec
- td (h->l) => 4.483 nSec
- tr => 9.446 nSec
- tf => 3.345 nSec
Q-:
- td (l->h) => 5.197 nSec
- td (h->l) => 8.245 nSec
- tr => 1.457 nSec
- tf => 1.600 nSec
Signal Rules:
- Minimum CLK pulse width = 15 nSec
- Minimum time from D change to down-edge of CLK = 13.85 nSec
|